A small sample is ground on a Tecator Cemotec 1090
Sample Mill. The reference test uses 2 g of ground wheat heated in an aluminum dish in a forced-draft oven for 40
min at 130, allowed to cool and weighed. AACC modified Method 44-16 (1) (OVENWMIST). Generally, 10% or 3
samples (whichever is higher) are used per nursery to obtain the oven wheat moisture. The results are averaged
and the mean is applied as the Wheat Moisture (WMIST), in the WAS system.